Fusion Splice Protection Sleeves

June 8th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A

Key Features:

  • Protects fusion splices from mechanical stress and environments factors
  • Stainless steel for for excellent tensile strength
  • Heat-shrinkable outer tube for superior sealing and duratibity
  • Easy and fast installation
  • Available in multiple lengths to suit various applications
  • Reliable performance for long-term network stability

 

Specifications

Model No. Length(mm) Inner Tube Diameter(mm) Outer Tube Diameter(mm) Steel Diameter(mm) Steel Material Color
GDI-FSPS-6154B 61/54 1.5 2.5 ± 0.1 1.2 304 Clear
GDI-FSPS-4540B 45/40 1.5 2.5 ± 0.1 1.2 304 Clear
GDI-FSPS-6154C 61/54 1.5 2.4 ± 0.1 1 304 Clear
GDI-FSPS-4540C 45/40 1.5 2.4 ± 0.1 1 304 Clear
GDI-FSPS-4035C 40/35 1.5 2.4 ± 0.1 1 304 Clear

Fast Connector SC APC (UPC)

June 8th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A

Pre-polished fast connectors designed for quick and reliable fiber termination. Compatible with single-mode fiber and various cable types including 0.9 mm tight buffer, 2 mm, and 3 mm drop cables. No adhesive or curing process required, allowing easy rework and reducing installation errors.

Key Features

  • Factory-installed fiber stub for consistent performance
  • Fast, easy field installation — no special tools required
  • Reusable and reworkable design reduces failure rates
  • No splicing or adhesive needed
  • Compatible with multiple cable sizes (0.9 / 2 / 3 mm)
  • Low insertion loss and high return loss
  • Reliable optical performance for stable connections

Standard Fast Connector

Specifications

Item Unit Parameter
Insertion Loss dB Max ≤ 0.5, Avg ≤ 0.3
Return Loss dB ≥ 45
Durability (1000 mating) dB Max 0.2
Operating Temperature °C -40 to +75
Storage Temperature °C -40 to +85

FC-SC/APC-A / FC-SC/UPC-A

Specifications

Item Unit Parameter
Insertion Loss dB 0.2
Return Loss dB ≥ 45
Durability (1000 mating) dB Max 0.1
Operating Temperature °C -40 to +80
Storage Temperature °C -40 to +85

 

Galvanized Steel Wire Strand

June 5th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A

High-strength galvanized steel wire strand designed for durability and long-term outdoor performance. Suitable for a wide range of applications including power transmission and telecommunications.

Applications:

  • Power transmission lines
  • Overhead conductors
  • Communication cables
  • Power distribution poles
  • Messenger strand / stay wire / guy wire / earth wire
  • ACSR cables
  • Agricultural and fencing applications (cattle, greenhouse, etc.)

 

Product Range

Diameter Wires Strength Zin Coating
1/8″ – 3/4″ 3-19 Up to 58,300 lbs A /B / C

Small

Diameter

Diameter 1/8″ – 3/16″
Wires 7
Strength 1330 – 2850 lbs
Zin Coating A / B / C

Medium

Diameter

Diameter 7/32″ – 9/32″
Wires 3-7
Strength 3500 – 8950 lbs
Zin Coating A / B / C

Large

Diameter

Diameter 5/16″ – 7/16″
Wires 7
Strength 6350 – 20800 lbs
Zin Coating A / B / C

Extra Large

Diameter

Diameter 1/2″ – 3/4″
Wires 7 – 19
Strength 24500 – 58300 lbs
Zin Coating A / B / C

 

Lite Tension Dead-End

June 5th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A

Key Features

  • Ideal for short spans and low mechanical loads
  • High-strength aluminum alloy wire for superior durability
  • Fast and easy installation
  • Neoprene-coated rods for added protection
  • ID tags indicate cable diameter
  • Designed for fiber optic cable support
  • Color-coded markings for easy identification
Model No. For Cable Diameter Length (L) Color Mark
Min (inch) Max (mm) Min (mm) Max (inch) Inch Meter
GDE-89/91 0.35 0.36 8.9 9.1 24 0.61 Black
GDE-95/105 0.37 0.41 9.5 10.5 28 0.71

Red

GDE-106/116 0.41 0.45 10.6 11.6 31 0.79 Orange

GDE-117/128 0.46 0.50 11.7 12.8 33 0.84

Green

GDE-129/141 0.50 0.55 12.9 14.1 37 0.94

Pink

GDE-142/156 0.55 0.61 14.2 15.6 42 1.07

Yellow

GDE-157/173 0.61 0.68 15.7 17.3 45 1.14

Blue

GDE-174/191 0.68 0.75 17.4 19.1 49 1.24

Brown

Tension Clamp

June 4th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A

Designed for secure fastening of low-voltage cables and multiple conductors, ensuring reliable performance without damaging the cable

Material: Metal / Nylon GA66

GDS 1500:

  • Cross-section: 50–70 mm²
  • Cable Diameter: 8.0–9.4 mm
  • Tension: 15KN
  • Material: Metal / Nylon PA66

GDS 2000:

  • Cross-section: 70-150 mm²
  • Cable Diameter: 9.4-13.8 mm
  • Tension: 15KN
  • Material: Metal / Nylon PA66

STA:
Cross-section: 1×10 / 1×16 mm²

STB
Cross-section: 2×16 / 2×25 mm²

STC:
Cross-section: 4×16 / 4×25 mm²

STD:
Cross-section: 1×16 / 1×70 mm²

LA2:
Cross-section: 2×6 / 2×16 mm²

DCR-1:
Cross-section: 1×4 / 1×25 mm²

LA2:
Cross-section: 2×6 / 2×16 mm²

DCR-1:
Cross-section: 1×4 / 1×25 mm²

Short Length Tenstion Clamp
Model: GAM08
Material: aluminum

Short Length Tension Clamp
Model: GA06
Material: aluminum/ nylon

Short Length Tension Clamp
Model: GA05
Material: Nylon

Model No. Cross-section (mm²) Tension Cable Diameter (mm) Material
GG1000A 16-35 10KN 4.5-6.6 Metal/Nylon GA66, aluminum alloy
GG1000 25-35 12KN 5.6-6.6
GG1500 50-70 15KN 8.0-9.4
GG2000 70-150 15KN 9.4-13.8
Model No. Cross-section (mm²) Cable Diameter (mm) Material
GG-1000 16-50 4.5-8 Metal/Nylon GA66, aluminum alloy
GG-2200 80-95 10.0-11.0
GGB-1 70-120 9.4-12.3

Aluminum Wire Holding

June 4th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A

Models & Specifications:

  • Model: G6308-00 Wire size: 0.138″ – 0.217″
  • Model: G6308-01 Wire size: 0.240″ – 0.272″

Key Features:

  • Lightweight, durable aluminum
  • Secure wire holding & tensioning
  • Ideal for outdoor & telecom use

G6200 – Aluminum Mounting Plate Assembly

June 4th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A

Key Features:

  • Durable aluminum construction
  • Bolt size: 5/8″
  • Supports up to 1-1/4″ banding straps
  • Compatible with a wide range of pole line hardware

G6310-01 – Guy Holding

June 4th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A


Specs:

  • Wire size: 0.102″–0.114″

Key Features:

  • For dead-ending strand wire
  • Holds ≥90% breaking strength
  • Reliable for aerial & outdoor use

G6213 – Tangent Support Assembly

June 4th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A


Key Features:

  • Includes 1 J-hook + 2 clamps
  • For distribution & coaxial cables
  • J-hook supports cable during install
  • Clamps grip messenger wire securely
  • Bolts/nuts sold separately
  • Use bolts 3″ longer than pole diameter

GK-6301 Tangent Support for ADSS Fiber

June 4th, 2026 Posted by No Comment yet

MANUAL

N/A

SPEC SHEET

N/A

USES

N/A



Lightweight and durable support solution for ADSS fiber in short-span, low-load applications, designed for reliable performance in outdoor environments.




Model No. Supported Cable Diameter
Min (in) Max (mm) Min (mm) Max (in)
GH301-01 0.41 11.6 10.5 0.46
GH301-02 0.43 13.0 11.0 0.51
GH301-03 0.59 17.0 15.0 0.66
GH301-04 0.67 19.0 17.0 0.74