Temperature Range:
- Transport/Storage Temperature: -20°C~ +70 °C
- Installation Temperature: -5°C~ +50 °C
- Operation Temperature: -20°C~ +70 °C
Cable Structural Characteristics:
- Low-bend-sensitivity fiber for high bandwidth and reliable transmission (ideal for indoor use)
- Parallel FRP strength members for strong crush resistance and fiber protection
- Simple, lightweight, and practical design
- Fluted structure for easy stripping, splicing, installation, and maintenance
- Low-smoke, zero-halogen, flame-retardant sheath
Attenuation:
| G6522 | ≤0.36dB/km @1310nm | ≤0.22dB/km @1550nm |
| G6555 | ≤0.40dB/km @1310nm | ≤0.23dB/km @1550nm |
| 50/125 | ≤3.3dB/km @850nm | ≤1.2dB/km @1300nm |
| 62.50/125 | ≤3.5dB/km @850nm | ≤1.2dB/km @1300nm |
Mechanical & Physical Properties:
| Outer sheath thickness | 1.7 mm |
| Inner sheath thickness | 0.8 mm |
| Cable weight | 40-65 kg/km |
| Max allowable working tension | 500 N / 1000N |
| Long/Short-term crush resistance | 300 N / 1000 mm |
| Min. bending radius (static) | 10D |
| Min. bending radius (dynamic) | 20D |
| Representative span | 8/100/120 m |
| Young’s modulus (full cable cross-section) | 8–20 GPa (depends on span/load) |